Skip to main content

Table 1 MRI sequence parameters

From: Advanced magnetic resonance imaging of chronic whiplash patients: a clinical practice-based feasibility study

Sequence

TR

TE

Slice thickness

Flip angle

Slice Spacing

NSA

ETL

BW

FOV

Matrix

Other

Parallel imaging

(ms)

(ms)

(mm)

(°)

(mm)]

  

(Hz/Pixel)

(mmxmm2)

(Grappa factor)

2D T2W FSE sag

4100

80

3

RFFA = 150

3.3 mm

2

17

355

220 × 220

224 × 320

DIXON

2

3D T2W SPACE sag

1500

101

0.8

140

2

66

324

250 × 250

602 × 640

2

2D T1W FSE sag

500

9

3

RFFA = 150

2

3

250

220 × 220

240 × 320

2

2D DWI trans (RESOLVE)

1088

60

4

180

4

920

220 × 220

160 × 160

b = 600 s/mm2

2

2D RG Phase-Contrast trans

26.3

9.88

8

20

2

745

140 × 140

192 × 192

VENC = 8–12

None

  1. T2W T2-weighted, T1W T1-weighted, TSE turbo spin echo, SPACE sampling perfection with application optimized contrasts using different flip angle evolution, DWI diffusion weighted imaging, RESOLVE readout segmentation of long variable echo trains, RG retrospective gated, sag sagittal, trans transversal, RFFA refocusing flip angle, VENC velocity encoding factor, TR repetition time, TE echo time, NSA number of signal averaged, ETL echo train length (turbo factor), BW bandwidth, FOW field of view